Korea Fire Institute of Industry & Technology
  • product Products List
    • home Home >
    • Pdoduct >
    • Products List
  • list image

  • Alarm valve
    The alarm valves of Shinyoung are optimized and essentially used for the wet sprinkler system. The y detect the flow of water and alert a fire alarm when there is a fire. The alarm valves of Shinyoung are carefully examined by KFI(Korea Fire Institute) undertaking strict internal pressure tests, functio nal examinations and visual inspections. The alarm valve is consisted of an alarm switch, pressure g auges, a clapper, and other pipes. In the state of the fire water line(fire pump- protection system)of an alarm valve is filled with wate r, the clapper operates once fire occurs. The alarm switch sends signals to the fire alarm control pan el once a setting time of delay circuit passes, and an alarm alert goes off.
    go to inquiry
  • list image

  • UL/FM Sprinkler
    Sprinkler is Paradises main product winning great internatinoal reputations for excellent technology and quality. Sprinkler has the most important roll in fire fighting and the heat sensitive material disintegrates itself when it reaches working temperature to spray the pressuried water to extinguish fire. Paradise has 16 different types of sprinklers, and the new flush type sprinkler is recognized as the most beautiful sprinkler in the world and the phantom sprinkler with the worlds one of a kind design has drawn great attention from the world for the quality as well as the design. Paradise sprinklers has the decisive role in minimizing the loss of lives and property by detecting and extinguishing fire in the early stage and letting people evacuate quickly. Sprinklers are the best implementations of the philosophy of Paradise, and we will continue to make quality improvements to prduce the products essential for protecting customers lives and property.
    go to inquiry
  • list image

  • WET TYPE VACUUM SPRINKLER SYSTEM
    KEY FEATURES: - Prevent damage caused by unintended water discharge - Negative pressure (vacuum) is maintained in the secondary pipe to arrest water outflow from holes in damaged (corroded) pipes and sprinklers or water leakage during maintenance APPLICATION: Areas where valuable assets or properties susceptible to damages caused by unintended water discharge are present such as: - Department store - Semiconductor factory - Clean room - Power plant - And many others
    go to inquiry
  • list image

  • SIDEWALL TYPE SPRINKLERS
    KEY FEATURES: - Uses environment-friendly glass bulb that contains special liquid for sprinkler activation at predefined temperature - Very stable operation against varying ambient temperature - Simple structure and beautiful aesthetics SPECIFICATIONS: Model No.: MGS68SW/93SW (Standard Response type) MGQ68SW/93SW (Quick Response type) Connection: 15A (PT 1/2") Orifice Size: 11.2 mm Test Pressure: 21 kgf/㎠ Flow Rate: 80L/min (at 1.0 kgf/㎠) Operating Temperature: 68℃ / 93℃ Max Ambient Temperature: 39℃ / 64℃ RTI: 81~350 (Standard Response type) below 50 (Quick Response type) Glass Bulb Color: R
    go to inquiry
  • list image

  • GLASS BULB PENDENT SPRINKLERS
    KEY FEATURES: - Uses environment-friendly glass bulb that contains special liquid for sprinkler activation at predefined temperature - Very stable operation against varying ambient temperature - Simple structure and beautiful aesthetics SPECIFICATIONS: Model No.: MGS68P/93P (Standard Response type) MGQ68P/93P (Quick Response type) Connection: 15A (PT 1/2") Orifice Size: 11.8 mm Test Pressure: 21 kgf/㎠ Flow Rate: 80L/min (at 1.0 kgf/㎠) Operating Temperature: 68℃ / 93℃ Max Ambient Temperature: 39℃ / 64℃ RTI: 81~350 (Standard Response type) below 50 (Quick Response type) Glass Bulb Color: R
    go to inquiry
  • list image

  • DRY PENDENT SPRINKLERS
    KEY FEATURES: - Designed to prevent water in the spinkler from being frozen APPLICATION: - For use in cold areas where water in the sprinkler maybe frozen - Parking spaces, outdoor sports complex and factories in cold areas SPECIFICATIONS: Model No.: MDFS72, MDGS68, MDGS68SW Connection: 25A (1" PT) Orifice Size: 11.2 mm Test Pressure: 25 kgf/㎠ Flow Rate : 80L/min (1.0 kgf/㎠) Operating Temperature : 72℃/105℃ (Flush), 68℃/93
    go to inquiry
  • list image

  • GLASS BULB UPRIGHT SPRINKLERS
    KEY FEATURES: - Uses environment-friendly glass bulb that contains special liquid for sprinkler activation at predefined temperature - Very stable operation against varying ambient temperature - Simple structure and beautiful aesthetics SPECIFICATIONS: Model No.: MGS68U/93U (Standard Response type) MGQ68U/93U (Quick Response type) Connection: 15A (PT 1/2") Orifice Size: 11.8 mm Test Pressure: 21 kgf/㎠ Flow Rate: 80L/min (at 1.0 kgf/㎠) Operating Temperature: 68℃ / 93℃ Max Ambient Temperature: 39℃ / 64℃ RTI: 81~350 (Standard Response type) below 50 (Quick Response type) Glass Bulb Color: R
    go to inquiry
  • list image

  • FLUSH TYPE SPRINKLERS
    - Uses special fusible alloy for sprinkler activation at predefined temperature - Excellent impact resistance and water sealing performance - Based on sophisticated and modern design that blends naturally with architectural aesthetics SPECIFICATIONS: Model No.: MFSC72/105 (Standard Response type) MFQC72/105 (Quick Response type) Connection: 15A (1/2" PT) Orifice Size: 11.3 mm Test Pressure: 21 kgf/㎠ Flow Rate: 80L/min (at 1.0 kgf/㎠) Operating Temperature: 72℃/105℃ Max Ambient Temperature: 39℃/64℃ RTI: 81~350 (Standard Response
    go to inquiry
  • list image

  • Sprinkler Head
    *Specifications -Model : JASP-8 -Size : PT½" -Flow Rate : 80LPM -Rating(Fushing Point) : 72
    go to inquiry
  • list image

  • Sprinkler Joint
    Sprinkler Joint: Max. Pressure 1.4MPa, Thread Dim. 25A(Material: STS304)
    go to inquiry
  • go list