Korea Fire Institute of Industry & Technology
  • product Products List
    • home Home >
    • Pdoduct >
    • Products List
  • list image

  • Pressure control switch
    Digital pressure switches have remedied its shortcomings that pressure chambers have difficulties in detailed setting. Digital pressure switches also can prevent water hammers and are excellent substitutes of pressure chambers. *Detailed setting of operation and stop points are possible(up to a second decimal place) * Minimize the place for installation * Terminating resistors are built and no need for a pressure gauge as discharge of pumps are shown * DC24V is needed * One device can control four pumps and easy to install and maintain * Pumps are operated in a consecutive order.
    go to inquiry
  • list image

  • PRE-ACTION VALVES
    * SIZE : 80A~150A 1. WORKING PRESSURE : 0.2MPa~1.4MPa 2. APPLICATION FLUID : WATER 3. HYDRAULIC TEST : 2.2 MPa 4. END CONNECTING : KS B 1511 10K FF FLANGED 5. ADHESION DIRECTION : VERTICAL 6.OPERATING TYPE : LATCHED CLAPPER SWING 7. ALARM SWITCH : PRESSURE SENSING(DC24V) 8. PILOT VALVE : MOV(OPEN TYPE DC24V) 9. MATERIALS : BODY GCD450, TRIM SSC13/C3771/EPDM
    go to inquiry
  • list image

  • ALARM VALVES
    * SIZE : 65A~150A 1. WORKING PRESSURE : 0.2MPa~1.4MPa 2. APPLICATION FLUID : WATER 3. HYDRAULIC TEST : 2.2 MPa 4. END CONNECTING : GROOVE JOINT 5. ADHESION DIRECTION : VERTICAL 6. FLOW INTEGER : 80 7. PRESSURE LOSS : MAX 20.7kPa 8. ALARM SWITCH : DELAY TIME 3~5sec M SENSING TYPE APPROACH SENSOR 9. MATERIALS : BODY GCD450, TRIM SSC13/C3771
    go to inquiry
  • list image

  • ALARM VALVES
    * SIZE : 65A~150A 1. WORKING PRESSURE : 0.2MPa~1.4MPa 2. APPLICATION FLUID : WATER 3. HYDRAULIC TEST : 2.2 MPa 4. END CONNECTING : KS 10K FF FLANGED 5. ADHESION DIRECTION : VERTICAL 6. FLOW INTEGER : 80 7. PRESSURE LOSS : MAX 20.7kPa 8. ALARM SWITCH : DELAY TIME 3~5sec M SENSING TYPE APPROACH SENSOR 9. MATERIALS : BODY GCD450, TRIM SSC13/C3771
    go to inquiry
  • list image

  • Flame Detector UX150
    Approvals : FM, KFI, IECEx - High Sensitivity UV/IR Dual detectors, Hydrogen Flame Detectors - Detects fire at distances up to 15Meters - 90º Horizontal and 90º Vertical Field of Vision
    go to inquiry
  • list image

  • Flame Detector RX500
    [General Information] - Approvals : FM, KFI, IECEx, CCCF (waiting certificate) - High Sensitivity Triple (Infrared) detectors - Detects fire at distances up to 50Meters - 90º Horizontal and 90º Vertical Field of Vision
    go to inquiry
  • list image

  • (FM) UV/IR Flame Detector RFD-2000X
    Detection range : 3-5 Seconds to 1 sq. ft. n-Heptane fire at 100ft(30m) Field of View : 90°, Cone type Explosion-proof : Exd IIB+H2 T6/T5 (IP67) Environment : (Operating temp) -40 ~ +75℃/T6, (Humidity) 0 ~ 95 Output : RELAY, Analog, RS-485 Enclosure Material : 316 Stainless Steel Opera
    go to inquiry
  • list image

  • FM Approvals Flame Detector
    Detection range : 3-5 Seconds to 1 sq. ft. n-Heptane fire at 200ft(60m) Field of View : 90°, Cone type Explosion-proof : Exd IIB+H2 T6/T5 (IP67) Environment : (Operating temp) -40 ~ +75℃/T6, (Humidity) 0 ~ 95 Output : RELAY, Analog, RS-485 Enclosure Material : 316 Stainless Steel Opera
    go to inquiry
  • list image

  • FM Approvals Flame Detector
    Detection range : 100ft(30m) Field of View : 90°, Cone type Explosion-proof : Exd IIB+H2 T6/T5 (IP67) Environment : (Operating temp) -40 ~ +75℃/T6, (Humidity) 0 ~ 95 Output : RELAY, Analog, RS-485 Enclosure Material : 316 Stainless Steel Opera
    go to inquiry
  • list image

  • Flame Detector(UV/IR)
    Detection range : 3-5 Seconds to 1 sq. ft. n-Heptane fire at 100ft(30m) Field of View : 100°, Cone type Explosion-proof : Exd IIC T6/T5 (IP66/67) Environment : (Operating temp) -40 ~ +75℃/T6, (Humidity) 0 ~ 90 Output : RELAY, Analog, RS-485 Enclosure Material : Aluminum 6061 Opera
    go to inquiry
  • go list